Measurement Range: -1.5 to 11.5″ H2O (-3.75 to 27.5 mbar)
Measurement Accuracy: ± 0.035% of Full Scale @ 25ºC (Includes zero, span, hysteresis and repeatability errors) Repeatability/Hysteresis: ± 0.015% Typical
Calibration Point Certainty: ± 0.012% Typical
Between Point Linearity: ± 0.01% Typical
Maximum Overpressure: 5 PSI (347 mbar)
Control Range: -10″ to 10″ H2O Standard (-25 mbar to 25 mbar)
System Accuracy: Lab Environment (@ 25ºC) ± 0.035% of Full Scale
(Combined Measure/Control) Field Operation (10 to 30ºC) ± 0.05% of Full Scale
Stability: ± 0.05% of Full Scale/Year
Temperature Range: Operational: 0ºC to 50ºC; Calibrated: 10ºC to 30ºC; Storage: -20ºC to 50ºC
Input Power Requirements: 105-135 VAC/210-270 VAC 50/60 Hz @ 48 VA
Battery Operation: 2.2 AHr Self-Contained NiCad
Operational (50% duty): Approximately 2 Hours
Display: 2 x 20 Alphanumeric Fluorescent Display: 0.2″ ( 5mm) H
Units: in H2O @ 20ºC, in H2O @ 4ºC, mm H2O @ 20ºC; in H2O @ 4ºC, cm H2O @ 20ºC, cm H2O @ 4ºC; in Hg @ 0ºC, Torr (mm Hg), cm Hg @ 0ºC, mBar Pascal, kPascal, PSI
Auto Zero Certainty: Microprocessor Governed Via Electropneumatic Control (Resident in RAM) Better Than ± 0.005% of Full Scale
Calibration: Factory Calibrated Against NIST Traceable Standard
Dimensions & Weight: 10″ Wide x 4.25″ High x 8.25″ Deep)
Warranty: 1 Year Parts & Labor (90 days for NiCad batteries)
Each Unit Includes
Manual
Line Cord
RS232 Cable
Manufacturer’s NIST Traceable Cert
Product Highlights
United Instruments Model # LPC-10
Measurement Range: -1.5 to 11.5″ H2O (-3.75 to 27.5 mbar)
Measurement Accuracy: ± 0.035% of Full Scale @ 25ºC (Includes zero, span, hysteresis and repeatability errors) Repeatability/Hysteresis: ± 0.015% Typical
Calibration Point Certainty: ± 0.012% Typical
Between Point Linearity: ± 0.01% Typical
Maximum Overpressure: 5 PSI (347 mbar)
Control Range: -10″ to 10″ H2O Standard (-25 mbar to 25 mbar)
System Accuracy: Lab Environment (@ 25ºC) ± 0.035% of Full Scale
(Combined Measure/Control) Field Operation (10 to 30ºC) ± 0.05% of Full Scale
Stability: ± 0.05% of Full Scale/Year
Temperature Range: Operational: 0ºC to 50ºC; Calibrated: 10ºC to 30ºC; Storage: -20ºC to 50ºC
Input Power Requirements: 105-135 VAC/210-270 VAC 50/60 Hz @ 48 VA
Battery Operation: 2.2 AHr Self-Contained NiCad
Operational (50% duty): Approximately 2 Hours
Display: 2 x 20 Alphanumeric Fluorescent Display: 0.2″ ( 5mm) H
Units: in H2O @ 20ºC, in H2O @ 4ºC, mm H2O @ 20ºC; in H2O @ 4ºC, cm H2O @ 20ºC, cm H2O @ 4ºC; in Hg @ 0ºC, Torr (mm Hg), cm Hg @ 0ºC, mBar Pascal, kPascal, PSI